HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W
HR-LS50W

1000MJ YAG Laser Q-Switch ND Tattoo Removal 532nm/1064nm/1320nm Laser Equipment Machine

1. 1064 nm laser is suitable for nevus of ota and coffee spot, freckles, moles, age spots, birthmark, traumatic pigmentation, dispel black tattoo, eyebrow, lip, eye, etc.

2. 532 nm laser is suitable for red or brown tattoos, eyebrow tattoo, lip liner, liner.And it can effectively fade red or brown birthmark and all kinds of shallow spots, etc.

3. 1320nm laser is suitable for skin tender skin whitening.

4. RED Target Light

$1200

icon No duties tax in most cases (USA)
Sign up to be a member if you would like to check order history from myChway shop
Contact us if you would like to make payment via Klarna
0
icon 

Warranty policy: the main machine for one year and parts such as handles for three months since delivery.

SKU: HR-LS50W

HR-LS50W

1000MJ YAG Laser Q-Switch ND Tattoo Removal 532nm/1064nm/1320nm Laser Equipment Machine

$1200

People who viewed this item also viewed

  • Description
  • Reviews (0)

Operation Theory


Adopting the Q-Switch ND YAG model, the equipment uses YAG to emit high energy instantaneously which smashing the pigment of pathological tissues, namely the YAG leading explosive effect: High energy emits instantaneously, making particular wavelength penetrating the epidermis and getting into pathological pigment tissues in only 6nms. Then pigments expand in top speed and explode. The superficial epidermis would be bounded our of a body; other parts of the pigments would split into granules which would be engulfed by macrophages, then exclude by the lymphatic system finally. The pigment becomes shallow gradually finally disappear while the surrounding normal skin tissues keep sound as they do not absorb a particular wavelength.

Operation Range


1.Pigment skin pathological changes, pigmentation caused by color pigment mixture, corium spot, freckle, mole, birthmark, nevus of Ota, etc.
2. Specialized in removing red capillary, coffee, brown and other colorized tattoos.
3. Effectively remove all kinds of embroider eyebrow, soak lip, eye line, and lip line.

Application


The system gem-adjusting Q switch can effectively cure the mixed pigments by pigment precipitation of extraneous source with pathological pigment change of endogenous source, inclusive of erroneous dark eyebrow-embroidery, lip-embroidery, lip-soak, eye line-embroidery, lip-line, tattoo (inclusive of tattoo by extraneous wounds), pigment precipitation by sensitive source, freckle on female's face (male's), coffee pot, old age spot, black mole, and birthmark in black, blue, purple, brown, red and etc. Operation course for different illness case as follows:
Operations
Operation course required ( cure times) Operation course interval Remark (requirements in surgery)
eyebrow-embroidery(eyeliner grain) 1 –2 times 30-60 days Eyebrow blow, eyeball protection
Eyebrow-embroidery ( eyeliner embroidery) 1-3 times 45-60 days Eyebrow blow, eyeball protection
Lip line (red dyed lip) 1-3 times 15-45 days Use 532 filter
Tattoo(caused by extraneous wounds) 1-4 times 30-60 days Blood infiltration will be fine on wounds
Freckle, age spot 1-4 times 15-30 days Blood infiltration will be fine on wounds
Birthmark, nevus/mole 3-7 times 45-90 days Must have Blood infiltration.

(1)Operation for a tattoo in eyebrow
The customer could not open eyes during Operation, the operator should adjust energy according to a depth of tattoo color, hold the handle and move it to Operation area slowly to make the customer feel acceptable in mentally. Right now, the speed of flash could be set 3HZ, keep head of the handle a two-finger distance to Operation area, start Operation from the head of the eyebrow to end of the eyebrow. It is needed to treat again in 5-10 minutes if the color of tattoo re-appear.

(2)Remove eye line
The speed of flashes could be set 4-5HZ, adjust the energy of light to minimum energy, keep a one-finger distance between the head of handle and Operation area. The operator should strictly protect customers’ eyes with the panel for eyelid or medical pledget (panel for eyelid)of 1cm depth.
The operation should be started from down eye line, the customer should deeply close eyes and keep eyeball up-sight inside. The operator should press the pledget (panel for eyelid) with forefinger and push up eyelid, peel down eyelid with a middle finger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eye line. Also, the customer should close eyes and keep eyeball down-sight inside. The operator should press the pledget (panel for eyelid) with the middle finger and push eyelid down, push eyelid up with the forefinger to bare the eye line, treat it with flashes of 4-5Hz.

(3)Remove lip line
The speed of flashes could be set 5Hz, keep a 3/4 finger distance between the head of handle and Operation area. It is better to remove black, coffee, deep, red and brown lip line with 1064 head at first time and then, treat again with 532 head.
Notice: All tattoos in lip should be treated in 6 months after making. OR removal Operation will fail. It should have 45-60 days interval to continue next Operation until removing all.

(4)Remove tattoo
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for Operation until Operation area seeps a little blood. It should have 45-90 days interval to continue next Operation until removing all.

(5)Remove spot and nevus
The speed of flashes could be set 3Hz/5Hz. Keep 3-4 fingers distance between the head of handle and Operation area. It is better to use high energy for Operation until Operation area seeps a little blood. It is advised to use 1064 head for normal spot and nevus Operation, but for deep color spot and nevus, it is better to use 532 head for Operation. It should have a 15-30 days interval to continue next Operation until removing all.

(6)Remove birthmark
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for Operation until Operation area seeps a little blood. It is advised to use 1064 head for birthmark Operation, but for red and deep color birthmark, it is better to use 532 head for Operation. It should have 45-90 days interval to continue

Specification


Cooling condition: wind system+closed circulating+cooling system
type: Q-switch Nd YAG With RED target light to aim at the skin.
The pulse energy: 0~2000mJ
Frequency:1-5Hz continuous adjustable
Dimension: 530*340*340(mm)
Power: 500W
Tips: 1064 nm & 532 nm and black doll tips

Packing List


1 x Main Unit
1 x Hand-piece
2 x Tips
1 x Black doll tip
1 x Water funnel
2 x Goggles (1 for the operator, 1 for the customer)
1 x Footswitch
1 x Holder
1 x Power line (we stock 110V-240V power version and US.UK.UA.EU plugs for the country all of the worlds)

0
0 Reviewed
Write A Review

There are no reviews yet.

icon
Be the first to review “1000MJ YAG Laser Q-Switch ND Tattoo Removal 532nm/1064nm/1320nm Laser Equipment Machine”

Your email address will not be published. Required fields are marked *

uploadUploaded successfully